Operating the UV-Detector Fig. 10 Smartline system (low pressure gradient with manual valve) Operating the UV-Detector Function of Foil Keys The foil key area (2) in Fig. 4 „Front panel of the UV-Detector “ consists of an AUTOZERO key, four arrow keys and a standby key. AUTOZERO-key Pushing this button will adjust the baseline. Knauer Webinar 1. Operators and service Manuals for instruments 2. experienced other people in the lab 3. Manufacturer of instruments or columns 4. KNAUER technical hotline: support@www.doorway.ru 5. Seminars, workshops and trainings: www.doorway.ru 6. Troubleshooting LC Systems by J.W. Dolan and L.R. Snyder, (Humana Press, ) 7. The Knauer Smartline Pump can be controlled using a PC. The user's manual for these pumps provide the necessary information to setup the communication. The presented LabVIEW driver incorporates all the commands provided by the user's manual. The test program uses some of the commands and offers common functionality to operate a single pump.
Smartline Pump Technical data are subject to change without notice. Visit www.doorway.ru for details on complete HPLC systems, HPLC columns, and osmometers. Wissenschaftliche Gerätebau. The KNAUER Smartline Pump can be supplemented with the Smartline Manager 's low pressure gradient module to achieve a quaternary low pressure gradient system. The addition of another Smartline Pump enables a high pressure gradient system (maximal quaternary). Eight programmable event outputs can be used for extensive switching tasks. The other approximately 99% of the HPLC eluate was directed to the PDA detector and subsequently diluted with 1 mL/min of water by means of a Knauer Smartline Pump (Knauer, Berlin, Germany), to a prospect 2 SPE-unit (Spark Holland, Emmen, The Netherlands).
The Smartline Preparative Pump is a versatile HPLC pump with an interchangeable pump head. This pump delivers constant flows up to ml/min at a maximum pressure of bar and is ideally suited for semi-preparative to preparative HPLC applications, including SMB purposes. Two to four pumps can be combined to create a high pressure. manual injection (see page 8) Tempering Column thermostats and column switching solutions (see page 10) The analytical HPLC and UHPLC systems of the KNAUER AZURA liquid chromatography instru-ments are designed to support and facilitate your work. Whether doing routine analysis or demanding separation tasks, AZURA systems are the right. The Smartline Pump is an isocratic HPLC pump to deliver an eluent or eluent mixture. It is suitable to be used as a dosing pump (e.g. for derivatization). With its pressure sensor the Smartline Pump allows for pressure protection of sensitive HPLC columns and to exactly shut off the pump at a definable maximum pressure for dosing.
0コメント